Clinical evidence

Six papers in leading radiology journals within two years

  • Radiology

    IF 17.6 · 3 papers

  • AJR

    IF 7.4 · 2 papers

  • European Radiology

    IF 6.0 · 1 paper

Based on 2025 Journal Citation Reports

Head-to-head study

AIRead-CXR and other medical-imaging VLMs

Lingshu · MAIRA-2 · MedGemma · MedVersa

Study conditions

  • Retrospective
  • Single tertiary-center ED
  • 478 patients
  • 3 blinded readers
  • Image-only inputs
  • Same-day CT reference

AcceptabilityHigher is better

Disagreement (RADPEER 3b)Lower is better

Hallucination rateLower is better

  • AIRead-CXR

    84.5%

    5.3%

    0.3%

  • Lingshu

    41.1%

    43.0%

    11.0%

  • MAIRA-2

    65.6%

    24.5%

    17.4%

  • MedGemma

    71.4%

    16.8%

    5.4%

  • MedVersa

    63.7%

    25.9%

    12.3%

  • Reference: radiologist reports

    74.3%

    13.9%

    0.1%

Reported as AIRead in the paper

Study design: 478 ED patients, same-day CT reference.

View the paper: European Radiology · 2026 , DOI link doi.org/10.1007/s00330-026-12648-8 (opens in a new tab)

The full record

Results by study

  1. Diagnostic Accuracy and Clinical Value of a Domain-specific Multimodal Generative AI Model for Chest Radiograph Report Generation

    View the paper: Radiology · 2025 , DOI link doi.org/10.1148/radiol.241476 (opens in a new tab)

    70.5%

    AI preliminary reports accepted without change

    Study detail

    70.5% of AI-written reports were used without a single edit, against 73.3% for radiologist reports and 29.6% for GPT-4V in the same evaluation.

    A retrospective evaluation on a defined test set.

    Study design

    • Retrospective
    • 42 hospitals
    • Training 8,838,719 pairs
    • Test 2,145 radiographs
    • 4 readers

    Comparators in the same study

    Radiologist reports
    73.3%
    GPT-4V reports
    29.6%
    Result in full
    70.5% of model-generated reports were accepted without change, compared with 73.3% of radiologist reports and 29.6% of GPT-4V reports. Reports from the model ranked highest in 60.0% of evaluations. The authors concluded that the model showed potential for preliminary interpretation support.
    Limitations
    A retrospective evaluation across a defined test set. This is evidence about the studied model and setting, not proof of performance at every institution.
    Paper title
    Diagnostic Accuracy and Clinical Value of a Domain-specific Multimodal Generative AI Model for Chest Radiograph Report Generation
  2. Value of Using a Generative AI Model in Chest Radiography Reporting: A Reader Study

    View the paper: Radiology · 2025 , DOI link doi.org/10.1148/radiol.241646 (opens in a new tab)

    19.8s

    Mean reading time with AI preliminary reports

    Study detail

    Reading with an AI report brought mean reading time down from 34.2 to 19.8 seconds, and agreement and report quality rose in the same study.

    A sequential retrospective design on a public dataset, with variability among individual readers.

    Study design

    • Retrospective sequential MRMC
    • Public dataset
    • 758 radiographs
    • 5 readers

    Comparators in the same study

    Same readers, without AI preliminary reports
    34.2s
    Result in full
    Mean reading time changed from 34.2 to 19.8 seconds. Agreement and quality scores improved statistically, while the paper noted variability among individual radiologists.
    Limitations
    A sequential retrospective design using a public dataset. The observed time and quality changes should not be generalised to every workflow.
    Paper title
    Value of Using a Generative AI Model in Chest Radiography Reporting: A Reader Study
  3. Clinical Validation of a Generative Artificial Intelligence Model for Chest Radiograph Reporting: A Multicohort Study

    View the paper: Radiology · 2025 , DOI link doi.org/10.1148/radiol.250568 (opens in a new tab)

    88.4%

    AI reports rated acceptable (standard criterion)

    Study detail

    Across ICU, emergency, health-checkup and outpatient cohorts, 88.4% of AI reports were clinically acceptable, against 89.2% for radiologist reports, a difference that was not statistically significant.

    The standard-criterion difference was not statistically significant, and under the stricter no-revision criterion AI reports were lower.

    Study design

    • Retrospective multicohort
    • ICU, emergency, health-checkup, public outpatient
    • 1,539 radiographs
    • 7 thoracic radiologists

    Comparators in the same study

    Radiologist reports · standard criterion
    89.2%
    AI preliminary reports · no-revision criterion
    66.8%
    Radiologist reports · no-revision criterion
    75.7%
    Result in full
    Under the standard criterion, acceptability did not differ statistically between AI and radiologist reports (88.4% vs 89.2%). Under the stricter no-revision criterion, AI reports were lower (66.8% vs 75.7%). In the compared cohorts, AI reports had higher sensitivity and lower specificity for referable abnormalities.
    Limitations
    Many reports required minor revision, and the surveyed radiologists did not regard the generated reports as a replacement for radiologist-written reports.
    Paper title
    Clinical Validation of a Generative Artificial Intelligence Model for Chest Radiograph Reporting: A Multicohort Study
  4. Multimodal Generative Artificial Intelligence Model for Creating Radiology Reports for Chest Radiographs in Patients Undergoing Tuberculosis Screening

    View the paper: AJR · 2025 , DOI link doi.org/10.2214/AJR.25.33059 (opens in a new tab)

    95.2%

    Sensitivity to TB-related abnormalities in AI preliminary reports

    Reader accuracy with AI: 91.3% → 93.5%

    Study detail

    Of the two radiologists reading tuberculosis-screening radiographs, one improved significantly in accuracy when reading with an AI preliminary report.

    A retrospective study of 800 radiographs from two public tuberculosis-screening datasets.

    Study design

    • Retrospective
    • 2 public TB-screening datasets
    • 800 radiographs
    • 2 readers

    Comparators in the same study

    Standalone AI report accuracy and localisation
    Lower than both readers
    Result in full
    Standalone AI report accuracy and localisation were lower than the readers'. Accuracy improved significantly with AI for one of the two readers.
    Limitations
    A retrospective study in which two readers read 800 radiographs from two public tuberculosis-screening datasets. Standalone AI report accuracy and localisation were lower than both readers'.
    Paper title
    Multimodal Generative Artificial Intelligence Model for Creating Radiology Reports for Chest Radiographs in Patients Undergoing Tuberculosis Screening
  5. Detection of Interstitial Lung Abnormalities on Chest Radiographs: Diagnostic Performance of Radiologists and Artificial Intelligence

    View the paper: AJR · 2026 , DOI link doi.org/10.2214/AJR.26.34686 (opens in a new tab)

    AUC 0.92

    Fibrotic ILA detection (CT reference standard)

    Mean 0.86 for five thoracic radiologists

    Study detail

    Interstitial lung abnormality is hard to catch on a chest radiograph even for radiologists. In this study AIRead-CXR performed comparably to them.

    ILA can be difficult to detect on Chest X-ray, even for radiologists.

    Study design

    • 1,168 individuals
    • 41 CT-confirmed ILA
    • CT reference standard
    • Radiologists vs AI
    Result in full
    For ILA, a finding that is difficult to detect on Chest X-ray, AIRead-CXR performed comparably to radiologists.
    Limitations
    This record is topic-specific research. It is neither broad validation of AIRead-CXR nor a screening indication.
    Paper title
    Detection of Interstitial Lung Abnormalities on Chest Radiographs: Diagnostic Performance of Radiologists and Artificial Intelligence
  6. Comparative Evaluation of Generative AI Models for Chest Radiograph Report Generation in the Emergency Department

    View the paper: European Radiology · 2026 , DOI link doi.org/10.1007/s00330-026-12648-8 (opens in a new tab)

    84.5%

    Clinical acceptability of AI preliminary reports (highest of 4 comparator VLMs)

    Study detail

    Of five medical-imaging VLMs evaluated under the same conditions, AIRead had the highest clinical acceptability and the lowest clinically significant disagreement.

    A single-center retrospective study with image-only model inputs.

    Study design

    • Retrospective
    • Single tertiary-center ED
    • 478 patients
    • 3 blinded readers
    • Image-only inputs
    • Same-day CT reference

    Comparators in the same study

    Radiologist reports
    74.3%
    The other four evaluated VLMs
    41.1–71.4%
    Result in full
    Among the five evaluated VLMs, AIRead had the lowest clinically significant disagreement and the highest clinical acceptability. Its hallucination rate was not statistically different from radiologist reports.
    Limitations
    A single-center retrospective study with image-only model inputs. Patient outcomes were not assessed, and human–AI collaboration was not directly evaluated.
    Paper title
    Comparative Evaluation of Generative AI Models for Chest Radiograph Report Generation in the Emergency Department

Next step